BC 6800 automated hematology analyzer - Small size, big difference.

• The ability to screen malaria

BC-6800 has a specific flag named "infected RBC?" And "InR (#, ‰)" to represent the number and proportion of infected red blood cells in the corresponding blood sample. Users of the BC-6800 may have information about the potential presence of malaria parasites, malaria agents. Because blood tests are almost mandatory for fever patients, and the increasing use of automated hematology analyzers, an automated method with good sensitivity and specificity to screen the presence of malaria parasites is very urgent, and has high practical and economic efficiency because it can detect malaria even when there is no suspicious sign. The BC-6800 enhances the effectiveness of the laboratory, helps detect malaria and supports early intervention and thus helps patients recover quickly.

• Ability to detect reticulocytes

RBC analysis with SF Cube technology distinguishes reticulocytes from mature red cells by its reaction to fluorescence. In addition to common parameters such as RET # and RET%, the BC-6800 also provides additional data related to premature reticulocytes (IRF), assisting in diagnosing anemia and monitoring reactions. of bone marrow to treat hematinic.

• Ability to detect RBC/PLT

Mixing eliminates air bubble formation - a persistent problem of traditional mixing methods, to ensure more accurate RBC results. The PLT-O result was not disturbed by small erythrocytes & debris, and large platelets due to fluorescent staining. This enhances data accuracy and sensitivity. PLT results are automatically adjusted when optical PLT count mode is used. The IPF parameter (immature platelet segment) indicates thrombopoiesis status in thrombocytopenia. It can also be used as an indicator of thrombopoietic activity in the bone marrow, similar to the use of reticulocyte counts in assessing anemia.

• Ability to detect HGB

The lenses convert the beam diverging into parallel beams, increasing the accuracy of the HGB measurement. The combination of LH lyse is stronger and the larger probe minimizes multiple WBC and lipid noise, the BC-6800 provides more reliable HGB results.

• Easy to use:

SPU with touch screen is used for sample processing, including standard, calibration & maintenance. PC DMU is only used for data management. Computer software allows easier operation and wider application.

• Easy to maintain:

Easily replace fluorescent reagents on the BC-6800 because the reagent compartment is placed on the front of the analyzer. The only maintenance the user has to do is turn off everyday using Probe cleanser, or use it every day in case of not turning off the device. In the case of 'no shutdown' the program "auto protection" prompts the user when it comes to the maintenance schedule.